Research Article
Resiliency-Driven Approach of DC Microgrid Voltage Regulation Based on Droop Index Control for High Step-Up DC-DC Converter
Table 3
Buck converter specifications.
| Symbol | Parameter | Values | 400 V bus side | 200 V bus side |
| Vi and Vo | Input and output voltages of converter | 400 V and 200 V | 200 V and 100 V | L | Filter inductance | 0.426 mH | 0.285 mH | C | Filter capacitance | 4 µH | 2.6 µH | | Switching frequency | 50 kHz | 50 kHz |
|
|