Research Article
An Assessment and Design of a Distributed Hybrid Energy System for Rural Electrification: The Case for Jamataka Village, Botswana
Table 1
Load demand calculation for Jamataka.
| S. no. | Category | Appliance | Power rating of appliances (W) | Number of appliances | Operating hours | AC load (kWh/d) |
| 1 | Households | Television | 150 | 40 | 3 | 18 | Decoder | 14 | 40 | 3 | 1.68 | Irons | 1500 | 30 | 2 | 90 | Radios | 100 | 70 | 3 | 21 | Washing machine | 1300 | 10 | 2 | 26 | Hair dryers | 1000 | 20 | 1 | 20 | Hair clippers | 15 | 50 | 2 | 1.5 | Electric stoves | 1200 | 30 | 6 | 216 | Electric kettles | 1500 | 40 | 2 | 120 | Fridges | 250 | 25 | 24 | 150 | Food blenders | 250 | 70 | 5 | 87.5 | Electrical sewing machine | 50 | 15 | 6 | 4.5 | Electrical welding machine | 250 | 10 | 1 | 2.5 | Laptops | 60 | 20 | 10 | 12 | Mobile phones | 5 | 320 | 11 | 17.6 | Light bulbs | 20 | 600 | 5 | 60 |
| 2 | School | Printer | 50 | 2 | 1 | 0.1 | Fan | 90 | 10 | 3 | 2.7 | Fridge | 250 | 1 | 5 | 1.25 | Desktop computer | 100 | 3 | 8 | 2.4 | Lamps | 20 | 40 | 12 | 9.6 |
| 4 | Businesses | Fan | 90 | 15 | 3 | 4.05 | Fridge | 250 | 5 | 24 | 30 | Lamps | 20 | 20 | 6 | 2.4 | Printer | 50 | 3 | 9 | 1.35 | Speaker | 2000 | 6 | 12 | 144 | TV | 150 | 6 | 3 | 2.7 |
| 5 | Churches | Fan | 90 | 20 | 3 | 5.4 | Lamps | 20 | 20 | 12 | 4.8 | Speaker | 2000 | 5 | 3 | 30 |
| 6 | Health post | TV | 150 | 1 | 9 | 1.35 | Fan | 90 | 10 | 4 | 3.6 | Fridge | 250 | 1 | 24 | 6 | Desktop computer | 100 | 2 | 16 | 3.2 | Lamps | 20 | 20 | 12 | 4.8 | Printer | 50 | 2 | 4 | 0.4 | Microscope | 100 | 2 | 6 | 1.2 |
| 7 | Police post | Desktop computer | 100 | 2 | 8 | 1.6 | Lamps | 20 | 15 | 12 | 3.6 | Fan | 90 | 5 | 4 | 1.8 | Total load (kWh/d) | 1116.58 |
|
|