Research Article

An Assessment and Design of a Distributed Hybrid Energy System for Rural Electrification: The Case for Jamataka Village, Botswana

Table 1

Load demand calculation for Jamataka.

S. no.CategoryAppliancePower rating of appliances (W)Number of appliancesOperating hoursAC load (kWh/d)

1HouseholdsTelevision15040318
Decoder144031.68
Irons150030290
Radios10070321
Washing machine130010226
Hair dryers100020120
Hair clippers155021.5
Electric stoves1200306216
Electric kettles1500402120
Fridges2502524150
Food blenders25070587.5
Electrical sewing machine501564.5
Electrical welding machine2501012.5
Laptops60201012
Mobile phones53201117.6
Light bulbs20600560

2SchoolPrinter50210.1
Fan901032.7
Fridge250151.25
Desktop computer100382.4
Lamps2040129.6

4BusinessesFan901534.05
Fridge25052430
Lamps202062.4
Printer50391.35
Speaker2000612144
TV150632.7

5ChurchesFan902035.4
Lamps2020124.8
Speaker20005330

6Health postTV150191.35
Fan901043.6
Fridge2501246
Desktop computer1002163.2
Lamps2020124.8
Printer50240.4
Microscope100261.2

7Police postDesktop computer100281.6
Lamps2015123.6
Fan90541.8
Total load (kWh/d)1116.58