Research Article
Semicentralized Power Sharing Scheme for Islanded Parallel-Connected Inverters
| Description | Symbol | Value |
| DC link voltage | VDC | 150 V | Reference voltage | Vref | 60 V (peak) | Switching frequency | fsw | 4.2 kHz | System frequency | f | 50 Hz | Sampling period | Td | 5 ms | Max power adjustment time | Tr | 300 ms | Filter inductance (all) | Lf | 2 mH | Filter capacitance (all) | Cf | 30 μF | Interface inductance 1 | Lint1 | 5 mH | Interface inductance 2 | Lint2 | 3.75 mH | Interface inductance 3 | Lint3 | 6.2 mH | Line impedance 1 | Zline1 | 0.3 Ω | Line impedance 2 | Zline2 | 0.2 Ω | Line impedance 3 | Zline3 | 0.4 Ω | Load 1 | Rload1 | 12 Ω | Load 2 | Rload2 | 5.6 Ω | Nonlinear load | Rnl | 30 Ω | Inverter 1 rating | | 0.5 kW | Inverter 2 rating | | 0.5 kW | Inverter 3 rating | | 0.8 kW | Part I—active power ratio | RP1 : RP2 : RP3 | 1 : 1 : 1 | Part I—reactive power ratio | RQ1 : RQ2 : RQ3 | 1 : 1 : 1 | Part II—active power ratio | RP1 : RP2 : RP3 | 1 : 2 : 4 | Part II—reactive power ratio | RQ1 : RQ2 : RQ3 | 1 : 1 : 1 |
|
|