Research Article
PV Based Standalone DC -Micro Grid System for EV Charging Station with New GWO-ANFIS MPPTs under Partial Shading Conditions
Table 1
Parameters used in simulation.
| Sl.no | Parameter | Value |
| 1 | PV MPP power | 213.15 W | 2 | PV MPP voltage | 29 V | 3 | PV MPP current ( | 7.35 A | 4 | Series PV panel | 4No’s | 5 | Parallel PV panel | 1No’s | 6 | Storage system battery type | Lead-acid | 7 | Storage system battery nominal voltage | 60 V | 8 | Storage system battery rated capacity | 16 Ah | 9 | SEPIC converter inductors | 1.6 mH | 10 | SEPIC converter coupling capacitor | 10 μF | 11 | Buck converter inductor | 3.3 mH | 12 | Bidirectional converter inductor | 2.4 mH | 13 | DC link capacitor | 60 μF |
|
|