Research Article
[Retracted] Assessing the Feasibility of Cogeneration Retrofit for Heating and Electricity Demands in Marine Diesel Engines
Table 5
Operating parameters of 34025 turbocharger diesel engine.
| Output power, W (kW) | Load ratio (%) | (K) | (K) | (kg/h) | Temperature ratio, | (K) | (K) |
| 8800 | 110 | 786.22 | 1886.71 | 44098.5 | 6.06 | 747.15 | 619.15 | 8000 | 100 | 761.90 | 1739.62 | 45965.8 | 5.61 | 708.15 | 599.15 | 6800 | 75 | 728.04 | 1603.38 | 45134.0 | 5.16 | 684.15 | 594.15 | 4000 | 50 | 623.46 | 1324.7 | 37760.0 | 4.28 | 658.15 | 620.15 | 2000 | 25 | 507.15 | 1063.6 | 30358.3 | 3.46 | 644.15 | 631.15 |
|
|