Research Article

A Reliable Visual Inspection Method for Vulnerability Assessment of Hyperstatic Structures Using Fuzzy Logic Analysis

Table 15

Degradation assessment card beam ends and exponent and safety.

Type of degradation Linguistic judgement Safety goal Safety exponent

spallingSmallSmall5.75
MediumSlightly small4.62
LargeMedium3.88

reinforcement corrosionSmallSlightly small5.62
MediumMedium4.50
LargeSlightly large3.50