Research Article
Validation of Microcirculatory Parameters Derived from the Standard Two-Compartment Model with Murine Xenografts Model
Table 3
Microcirculatory parameters (mean ± standard deviation) estimated by the standard two-compartment model for each type of xenograft.
| Type of xenograft | (mL/min/100 mL) | PS (mL/min/100 mL) | (%) | (%) |
| HCC | 28.73 ± 6.74 | 3.98 ± 2.00 | 0.89 ± 0.44 | 7.18 ± 2.75 | Gastric | 60.59 ± 30.32 | 4.22 ± 1.50 | 1.70 ± 0.86 | 7.90 ± 1.53 | Lung | 51.25 ± 18.99 | 6.00 ± 2.43 | 4.06 ± 1.03 | 17.29 ± 4.06 | RCC | 164.15 ± 1.05 | 6.27 ± 4.17 | 4.56 ± 0.08 | 10.87 ± 7.95 | GIST | 26.83 ± 4.01 | 3.07 ± 1.13 | 0.82 ± 2.28 | 22.92 ± 2.28 | Colorectal | 27.86 ± 9.29 | 3.68 ± 1.61 | 2.79 ± 1.60 | 14.78 ± 17.81 | Pancreas | 34.64 ± 4.00 | 7.39 ± 0.21 | 2.02 ± 0.05 | 12.80 ± 5.84 | SCC | 98.99 | 11.8 | 5.18 | 22.75 |
|
|