Journal of Geological Research / 2014 / Article / Tab 1 / Research Article
The Influence of Sewage System on the Functioning and Quality of Krakow’s Watercourses Table 1 Levels of pH, oxidizing-reducing potential Eh, and electrolytic conductivity EC of the sediments collected in the Wilga, Prądnik, and at Wola Justowska (park—the reference area).
Sample symbol pH level Eh [mV] EC mS/cm Cd Pb mg/kg0.18–0.063 <0.063 0.18–0.063 <0.063 mmWilga catchment area 1W 5.43 −85 1.99 3 8 38 107 2W 6.67 −165 1.36 3 7 45 104 3W 6.76 −235 1.00 4 6 40 117 4W 7.9 −88 1.67 no fraction 10 no fraction 93 5W 7.95 −120 1.71 2 5 28 68 6W 6.68 −132 1.09 3 7 15 107 7W 6.28 −262 1.04 5 7 88 114 8W 6.68 −205 1.73 3 6 50 111 9W 6.83 −150 1.90 2 5 53 102 10W 7.61 −76 1.37 3 2 7 24 11W 6.14 −113 1.63 2 4 20 75 12W
6.49 −290 2.00 4 7 59 105 13W 7.78 −75 0.49 2 5 36 77 14W 6.27 −140 1.68 3 7 24 89 Prądnik catchment area 1P 10.21 −3 1.09 5 7 59 116 2P 9.08 −110 0.49 8 8 126 191 3P 7.60 −14 1.45 10 10 72 57 4P 8.20 −287 1.83 7 6 120 133 5P — — 8.60 8 6 145 73 6P 6.82 −165 6.29 5 6 91 104 7P 6.23 341 0.58 7 2 85 31 8P 7.48 −91 — 3 4 45 63 9P 6.28 −169 9.10 4 4 55 54 10P 5.93 130 5.93 4 3 77 53 11P 7.61 82 — 2 4 52 147 12P 7.64 −153 0.87 10 5 161 79 Wola Justowska area 1R 7.14 −130 1.87 3 3 61 58 2R 7.84 177 0.89 5 6 116 135 3R 7.53 62 0.51 4 4 78 129 4R 7.57 −172 1.03 3 5 41 114 5R 8.24 131 0.35 4 3 53 80 6R 7.31 −211 0.43 5 5 72 100