| | Line 1 | Line 2 | Line 1 + Line 2 |
| Base simulation model | | | | Production (units) | 169,400 | 176,232 | 345,632 | Energy consumption (kWh) | 610,737 | 634,238 | 1,244,975 | Cost () | 366,442 | 380,543 | 746,985 | kWh/unit | 3.61 | 3.60 | 3.60 | €/unit | 2.16 | 2.16 | 2.16 | 10% energy savings on refiners scenario | | | | Production (units) | 169,400 | 176,232 | 345,632 | Energy consumption (kWh) | 589,972 | 610,443 | 1,200,415 | Cost (€) | 353,983 | 366,266 | 720,249 | kWh/unit | 3.48 | 3.46 | 3.47 | €/unit | 2.09 | 2.08 | 2.08 | Overall savings | | | | kWh saved/month | 20,765 | 23,795 | 44,560 | € saved/month | 12,459 | 14,277 | 26,736 | kWh saved/year | 249,180 | 285,540 | 534,720 | € saved/year | 149,508 | 171,324 | 320,832 | % kWh saved | 3.40% | 3.75% | 3.58% | % kWh/unit saved | 3.60% | 3.89% | 3.61% | % €/unit saved | 3.24% | 3.70% | 3.70% |
|
|