Research Article

Columnar-to-Equiaxed Transition in Metal-Matrix Composites Reinforced with Silicon Carbide Particles

Table 3

Predicted and measured CET positions for different composites.

Experiment numberAlloy and compositeCETpredicted (mm)CETmeasured (mm)Relative error (%)

1Zn-27 wt.% Al (ZA27)91865.49
2Zn-27 wt.% Al (ZA27)47454.25
3ZA27 + 5vol% SiC52479.61
4ZA27 + 5vol% SiC69655.79
5ZA27 + 8vol% SiC50476.02
6ZA27 + 8vol% SiC46428.69
7ZA27 + 16vol% SiC57537.01
8ZA27 + 16vol% SiC45426.66