Research Article

Gradient Artefact Correction and Evaluation of the EEG Recorded Simultaneously with fMRI Data Using Optimised Moving-Average

Table 3

Median SNR and MSE considering the evaluation of the EEG preservation according to the scheme of Figure 6.

MethodPhilips dataGE data
SNRMSE (µV2)SNRMSE (µV2)

OMA0.99990.14980.99931.1062
AAS0.99902.30310.99607.1058