Comparison of the measured temperatures in the “heat affected zone” and the maximum temperature in the simulation.

Time [s]/power [W]Measured temperature [°C]Standard deviation [%]Simulated temperature [°C]

0.1/160419.5347.08320.86
0.25/70417.4210.57286.34
0.25/90471.8926.32362.00
0.25/120503.4221.54476.00
0.5/50485.7126.96303.39
0.5/70522.758.13418.05
0.5/90500.0914.4532.98
0.75/50498.805.98367.76
0.75/70498.553.34510.95
1.00/50537.884.11419.45