Research Article

Risk-Based Allowed Outage Time and Surveillance Test Interval Extensions for Angra 1

Table 10

Overview of the AOT and STI extensions.

SystemAOT extension to 168 h without compensatory measuresAOT extension to 168 h with compensatory measuresSTI extension to 3 months without compensatory measuresSTI extension to 3 months with compensatory measures

SISNoYes (restrictions applied)Yes (no restrictions)Not applicable
SWSNoYes (no restrictions)Yes (restrictions applied)Yes (no restrictions)
AFWSNoNoYes (restrictions applied)Not applicable