Research Article
Fuzzy RAM Analysis of the Screening Unit in a Paper Industry by Utilizing Uncertain Data
Table 7
Range of RAM-Index when parameters of components varies separately.
| Component | Range of scale parameter (hrs) | RAM-Index | Range of repair time (hrs) | RAM-Index |
| Filter | 286.45–387.55 | Min: 0.97465822 | 1.70–2.30 | Min: 0.97342489 | Max: 0.97667539 | Max: 0.97787954 |
| Screener | 267.75–362.25 | Min: 0.97417942 | 3.40–4.60 | Min: 0.97294317 | Max: 0.97680809 | Max: 0.97831576 |
| Cleaner | 399.50–540.50 | Min: 0.97569885 | 1.70–2.30 | Min: 0.97569885 | Max: 0.97569885 | Max: 0.97569885 |
| Decker | 214.20–289.80 | Min: 0.97324561 | 4.25–5.75 | Min: 0.97298904 | Max: 0.97743319 | Max: 0.97827127 |
|
|