Research Article

Fuzzy RAM Analysis of the Screening Unit in a Paper Industry by Utilizing Uncertain Data

Table 8

Range of RAM-Index when parameters of components varies simultaneously.

Component Range of scale
parameter (hrs)
Range of repair time (hrs) RAM-Index

Filter 286.45–387.55 1.70–2.30 Min: 0.98675020
Max: 0.99197856

Screener 267.75–362.25
3.40–4.60 Min: 0.95034946
Max: 0.97417884

Cleaner 399.50–540.50 1.70–2.30 Min: 0.99011339
Max: 0.99565120

Decker 214.20–289.80 4.25–5.75 Min: 0.92456143
Max: 0.95706339