Table of Contents
Journal of Radiotherapy
Volume 2014 (2014), Article ID 343979, 7 pages
http://dx.doi.org/10.1155/2014/343979
Research Article

FLUKA Monte Carlo for Basic Dosimetric Studies of Dual Energy Medical Linear Accelerator

1Department of Physics, University & INFN of Torino, Via P.Giuria, 10125 Torino, Italy
2Department of Radiation Therapy, HCG-Dr. Balabhai Nanavati Hospital, Vile Parle (West), Mumbai 400 056, India
3Department of Physics, Noorul Islam Centre for Higher Education, Kumaracoil, Thuckalay, Kanyakumari District, Tamilnadu 629 180, India
4Department of Physics, University of Calicut, Thenhipalam, Kerala 673635, India
5Department of Radiation Therapy, K.S Hegde Medical Academy, Nitte University, Deralakatte, Mangalore, Karnataka 575018, India
6Department of Radiation Therapy, AJ Cancer Institute-Kuntikana, Mangalore, Karnataka 575004, India

Received 29 January 2014; Revised 9 July 2014; Accepted 9 July 2014; Published 24 July 2014

Academic Editor: Tibor Major

Copyright © 2014 K. Abdul Haneefa et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. D. Sheikh-Bagheri and D. W. O. Rogers, “Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters,” Medical Physics, vol. 29, no. 3, pp. 379–390, 2002. View at Publisher · View at Google Scholar · View at Scopus
  2. F. Verhaegen and J. Seuntjens, “Monte Carlo modelling of external radiotherapy photon beams,” Physics in Medicine and Biology, vol. 48, no. 21, pp. R107–R164, 2003. View at Publisher · View at Google Scholar · View at Scopus
  3. A. Mesbahi, M. Fix, M. Allahverdi, E. Grein, and H. Garaati, “Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: a comparison between MCNP4C, GEANT3 and measurements,” Applied Radiation and Isotopes, vol. 62, no. 3, pp. 469–477, 2005. View at Publisher · View at Google Scholar · View at Scopus
  4. A. Mesbahi, A. J. Reilly, and D. I. Thwaites, “Development and commissioning of a Monte Carlo photon beam model for Varian CL 2100EX linear accelerator,” Applied Radiation and Isotopes, vol. 64, no. 6, pp. 656–662, 2006. View at Publisher · View at Google Scholar · View at Scopus
  5. T. D. Solberg, J. J. DeMarco, I. J. Chetty et al., “A review of radiation dosimetry applications using the MCNP Monte Carlo code,” Radiochimica Acta, vol. 89, no. 4-5, pp. 337–355, 2001. View at Google Scholar · View at Scopus
  6. M. K. Fix, P. Manser, E. J. Born, R. Mini, and P. Rüegsegger, “Monte Carlo simulation of a dynamic MLC based on a multiple source model,” Physics in Medicine and Biology, vol. 46, no. 12, pp. 3241–3257, 2001. View at Publisher · View at Google Scholar · View at Scopus
  7. S. Y. Lin, T. C. Chu, and J. P. Lin, “Simulation of a clinical linear accelerator,” Applied Radiation and Isotopes, vol. 55, pp. 759–765, 2001. View at Google Scholar
  8. S. B. Jiang, T. Pawlicki, and C. M. Ma, “Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculations,” Physics in Medicine and Biology, vol. 45, no. 8, pp. 2151–2161, 2000. View at Publisher · View at Google Scholar · View at Scopus
  9. Y. Huang, R. A. Siochi, and J. E. Bayouth, “Dosimetric properties of a beam quality-matched 6 MV unflattened photon beam,” Journal of Applied Clinical Medical Physics, vol. 13, no. 4, pp. 71–81, 2012. View at Google Scholar · View at Scopus
  10. L. Wang, E. Yorke, G. Desobry, and C. Chui, “Dosimetric advantage of using 6 MV over 15 MV photons in conformal therapy of lung cancer: monte carlo studies in patient geometries,” Journal of Applied Clinical Medical Physics, vol. 3, no. 1, pp. 51–59, 2002. View at Google Scholar · View at Scopus
  11. G. Battistoni, S. Muraro, P. R. Sala et al., “The FLUKA code: description and benchmarking,” in Proceedings of the Hadronic Shower Simulation Workshop, M. Albrow and R. Raja, Eds., vol. 896 of AIP Conference Proceeding, pp. 31–49, September 2007.
  12. A. Ferrari, P. R. Sala, A. Fasso, and J. Ranft, FLUKA: A Multi-particle Transport Code, CERN-2005-10, INFN/TC_05/11, SLAC-R-773, 2005.
  13. V. Vlachoudis, “FLAIR: a powerful but user friendly graphical interface for FLUKA,” in Proceedings of the International Conference on Mathematics, Computational Methods Reactor Physics (M&C '09), Saratoga Springs, NY, USA, 2009.
  14. R. Brun and F. Rademakers, “ROOT—an object oriented data analysis framework,” in Proceedings of the AIHENP Workshop on Nuclear Instruments and Methods in Physics Research A, pp. 81–86, Lausanne, Switzerland, September 1996, http://root.cern.ch/.
  15. J. Venselaar, H. Welleweerd, and B. Mijnheer, “Tolerances for the accuracy of photon beam dose calculations of treatment planning systems,” Radiotherapy and Oncology, vol. 60, no. 2, pp. 191–201, 2001. View at Publisher · View at Google Scholar · View at Scopus
  16. C. L. H. Siantar, R. S. Walling, T. P. Daly et al., “Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantom,” Medical Physics, vol. 28, no. 7, pp. 1322–1337, 2001. View at Publisher · View at Google Scholar · View at Scopus