Research Article

Intelligent Photovoltaic Maximum Power Point Tracking Controller for Energy Enhancement in Renewable Energy System

Table 3

Performance comparison of the experimental output voltages of the various proposed and conventional boost converters.

Boost converter topology
Input voltage (V)Duty cycleConventionalProposed
Input current (A)Output current (A)Output voltage (V)Input current (A)Output current (A)Output voltage (V)

300.20.40.21402.580.54116
0.30.510.25453.730.67140
0.40.690.3536.720.85200

500.20.730.42674.560.9218
0.30.90.47746.811.15261
0.41.170.538611.021.5327

1000.21.20.691368.651.86415
0.31.450.7415513.032.3510
0.41.870.8318221.242.96646

2000.22.141.2727318.34.13798
0.32.731.4331023.614.39936
0.43.711.6836130.164.821072