Research Article
An Analytical Model for Optimizing the Combination of Energy Sources in a Single Power Transmission Network
Table 3
Case study technical parameters.
| Technologies | Capacity factor | Efficiency | Ramp Rate/Max. var. |
| NGCC | 85% | 47% | 5%/min | NGCC Flexible | 87% | 61% | 10%/min | OCGT Flexible | 32% | 36% | 13%/min | PC | 84% | 38% | 1–3%/min | PV | 25% | — | 50%/min | CSP | 18% | 13.5% | — | Wind | 34% | — | 30%/min |
|
|