Research Article

An Analytical Model for Optimizing the Combination of Energy Sources in a Single Power Transmission Network

Table 6

Evaluation model for NGCC + wind combination.

Plant # 1Plant # 2Plant # 1 size (MW)Wind energy shareNominal efficiencyOverall efficiency Efficiency variationInternal interest rate

NGCC Wind 3008%55%54%−1%19%
6%55%58%3%22%
3%55%57%2%25%
2108%55%54%−1%19%
5%55%57%2%23%
2%55%56%1%25%
1508%55%54%−1%18%
5%55%58%3%22%
3%55%57%2%24%