Research Article
Inherent Difference in Saliency for Generators with Different PM Materials
Table 3
Comparison of overload operation for the two generators.
| Characteristics | G1-Nd | G2-Fe |
| Max. torque (kNm) | 200.4 | 178.0 | Load angle at max torque (°) | 46.2 | 44.1 | Max. power (kW) | 607.5 | 551.1 | Load angle at max. power (°) | 43.2 | 41.4 | Voltage drop at 600 A (% of no load voltage) | 28 | 37 |
|
|