Research Article

Energy Efficient Hybrid Dual Axis Solar Tracking System

Table 3

Power values of static and tracking panel and the corresponding power gain by tracking panel over static panel at different times in a day.

Time
(hour)
Static panelHybrid
tracking panel
Continuous
tracking panel
Power gain by
hybrid tracking system
over static panel
Power gain by
continuous tracking system
over static panel
Power gain by
continuous tracking system
over hybrid tracking system
Power
(watt)
Power
(watt)
Power
(watt)
%%%

7:300.86021.32941.504835.2941242.8362611.65603
8:001.09481.64221.821633.3333339.8989911.65603
8:301.72261.87921.8968.3333339.145579.848485
9:002.1332.722.821.5808823.821430.886076
9:302.77553.11223.112210.8187110.818712.857143
10:003.08883.24723.24724.8780494.8780490
10:303.23083.40563.40565.1327235.1327230
11:003.5463.5463.546000
11:303.62483.62483.6248000
12:003.62483.78243.78244.1666674.1666670
12:303.70363.78243.942.08333312.24490
13:003.38843.78243.861210.4166712.24494
13:303.1083.67073.748815.329517.093472.040816
14:002.57073.52353.647827.0412929.527392.083333
14:302.00463.39243.445240.9090941.81473.407533
15:001.37342.87122.92352.1663453.014031.532567
15:301.05562.3872.436655.7771356.677341.772152
16:000.82721.93252.043657.1953459.522412.035623
16:300.66691.46491.54254.4747156.750975.436485
17:000.51730.99451.156547.9839155.270215
17:300.29320.60.76451.1333361.6230414.00778