Base values used for the comparison of the LUCE of the DSWES and the SWES.

Input parameterSWESDSWES

Useful life of wind electric generator (years)2020
Useful life of wind turbine inverter and controller (years)1010
Useful life of civil works (years)2020
Useful life of battery bank (years)77
Annual O&M of DSWES/SWES as a fraction of its capital cost0.020.04
Discount rate as a fraction0.100.10