Table 1

Construction and operational parameters of fuel cells presented in Figure 2.

Fuel Cellabc

Active Area (cm2)161616
Flow fieldStraight-ParallelStraight-ParallelStraight-Parallel
FuelHydrogenHydrogenHydrogen
OxidantOxygenOxygenOxygen
Relative Humidity ()100100100
Catalyst Load (mg/cm2)Pt 0.5Pt 0.5Pt 0.5
Stack power (W)172027
Temperature (°C)312730
Unit cells121418