Abstract

Early failures in bearings of wind turbine drivetrains have increased after introduction of power electronic switches, which leads to shaft voltages and bearing currents. In presence of voltage, a rupture of bearing insulation could occur due to several plausible electro-physical mechanisms viz., asperities, electric breakdowns, particles, etc. The flow of high amperage current through the bearing during a breakdown mechanism could lead to early failures. Our aim is to understand the electrical behaviour of a bearing and elaborate by an equivalent electric circuit model, emphasizing on particle-initiated breakdowns. In presence of a shaft voltage, the particles form a path of low resistance through the bearing and results in flow of shaft or bearing currents, which could cause pre-mature failure of the bearing. Particles such as Arizona Test Dust (ATD), carbon black, aluminium powder and fine iron powder were mixed in lubricant at particle concentrations ranging between 7.5 mg/L and 150 mg/L. The breakdown characteristics of electrical insulation of the bearing during a given test is quantified as time of conduction, which is expressed as a percentage of the time the bearing is in the conducting state during a test. An investigation of time of conduction for different lubricant samples was conducted along with studying the effects of start and stops of the rotating shaft. The electrical conductive nature of the particle played no role in breakdown of bearing voltage. At a fixed concentration of 150 mg/L, the insulation breakdown events were highest in lubricant with ATD, followed by iron powder, aluminium power and carbon black particles. The time of conduction increases up to 24 times for the same test lubricant, as the particle concentration was increased from 7.5 mg/L to 150 mg/L. The current activity reduced to almost half in the test after stopping the shaft rotation. The resistance of bearing during insulation breakdown events is highest for aluminium powder, followed by fine iron powder, carbon black and ATD.

1. Introduction

Failure analyses of electrical machines have revealed that prematurely failed bearings have been the leading cause for downtimes not only in wind power generation industry [1, 2], but also petroleum and chemical industries [35]. The high failure rate in bearings also result in large downtimes, which increases costs and reduces feasibility of energy generated from wind turbines. Thus, higher reliability of bearings is important, and their pre-mature failures should be reduced. These pre-mature failures have already been linked to the presence of additional electrical stress in the form of stray bearing currents and voltage across the bearing [6]. The stray bearing currents are commonly classified as: (i) Capacitive bearing currents [712], (ii) Capacitive discharge currents also popularly knowns as Electrostatic Discharge Machining (EDM) type of bearing currents [7, 1317], (iii) High Frequency (HF) circulating type of bearing currents [7, 11, 12, 1820], (iv) HF ground currents [7, 21], and (v) Ohmic currents [7, 22].

At speeds higher than few 100’s of rpm, the bearing rolls over a thin film of lubricant that bears the load of operation. Since the lubricating film formed around the rolling element is electrically insulating in nature, the bearing could withstand certain voltage across its inner and outer raceways; commonly referred to as bearing voltage. If the bearing voltage exceeds a certain threshold value, a path of low resistance is formed between the bearing raceways and could lead to a flow of high amperage bearing currents. The source of voltage in this case is caused by charging of stray capacitance within the machine due to the common mode voltage source and causes capacitive discharge currents. Presence of particles and debris reduces the threshold voltage for causing breakdown events in the bearing. The flow of higher amperage HF circulating types of bearing currents through the bearing initiated due to the presence of particles is commonly found in larger machines and is known to cause premature failures in bearings [7]. The introduction consists of three parts; (1) proposed equivalent electrical circuit model of bearing, (2) plausible mechanisms leading to electrical breakdown in bearings, and (3) electrical circuit models of bearings reported in literature.

1.1. Equivalent Electrical Circuit Model of Bearings

The overall goal of our research is to increase the understanding of how bearing currents are initiated in a steel bearing in presence of electrical voltage, from an electro-physical perspective. In addition, investigating the electrical properties of bearings at different operating points is also a part of the overall goal. To fulfil this, we have proposed an equivalent electrical circuit model of the bearing based on its electrical behaviour as a function of different operating points. Thus, the bearing is electrically modelled as a system of several electrical component with two main electrical states, insulating and conducting. The components of these two electrical states are investigated as a function of operating points. The equivalent circuit model is presented in Figure 1, while similar electrical circuit models have also been reported in [13, 23]. In this paper, we have experimentally investigated the electrical behaviour and properties of a miniature bearing with focus on particle-initiated breakdowns, i.e., findings limited to the conducting state properties under influence of particle-initiated electrical breakdowns are reported.

In the insulating state, as the bearing operates in EHL regime, the bearing can be represented by a parallel connection of a capacitance, , and a resistance, . The capacitance is determined by the bearing size and geometry as well as the relative permittivity of the lubricant. Thus, the can change due to temporary changes in the physical, chemical or electrical properties of the film during operation and an elastic deformation in bearing. The bearing current driven by common mode voltage then mainly flows capacitively through the bearing in insulating state. In parallel to the capacitance, a resistance, , is connected, representing all kind of losses in the lubricant, such as conductive losses but also possible polarization losses of components inside a bearing. The lubricant film thickness is generally in the order of 0.2–2 μm [24], and changes with the bearing type.

In conducting state, a breakdown mechanism forms a low resistive path, electrically bridging bearing raceways, which represents a temporary closing of the switch of the electrical circuit shown in Figure 1. In the event of a breakdown, the resistance of the bearing in conducting state is much lower than impedance in insulating state. The total current will consist of two components, a capacitively driven current through the machine stray capacitances and a discharge current due to discharge of the machine stray capacitances. Bearing resistance, is given by the ratio of the measured bearing voltage and bearing current.

The lubricating film thickness during operation is in the range of 0.2–2 µm in a running bearing. A voltage of few 10’s of volts [6] thus results in high electric fields (up to 100 V/µm) in the sub-micron lubricating film, and an insulation breakdown of the film results in heating, evaporation of lubricant, melting of bearing steel and crater formation on bearing surfaces.

To obtain a resistively flowing current through the bearing, two conditions must be fulfilled: (i) a breakdownmechanism that provides a temporary electrical path through the insulating bearing lubricant and, (ii) a shaft voltage that drives a current through the path established. When this occurs, the voltage across the bearing, i.e., the bearing voltage, drops to a small value, determined by the resistance of the conducting path ().

1.2. Electrical Breakdowns Mechanisms inside Bearing

A breakdown event inside the bearing provides a low impedance path for the flow of bearing currents, leading to its premature failure. Different types of bearing currents can flow through the bearing during the breakdown of electrical insulation of the bearing. An insulation breakdown could occur inside the bearing due to several plausible mechanisms such as, (i) asperity contacts, (ii) electrical breakdown of lubricating film, and (iii) contamination and solid particles.

Frequent asperity contacts during bearing operation leads to discharge of any bearing voltage present between the inner and outer raceways of the bearing. The asperities (local peaks) on the metallic surfaces of the raceways and rolling element make frequent physical contacts to provide a path for flow of ohmic current through the bearing. Frequent asperity contacts are present at low rotational speeds, but are not influential at higher rotational speeds because an oil film separates the interacting surfaces inside the bearing.

Electrical breakdown of the lubricating film also leads to formation of conducting path between the inner and outer raceways of the bearing and occurs when the bearing voltage crosses a threshold [7, 1317]. The breakdown phenomenon could also be treated similar to electric breakdown of insulating oils [2531]. This assumption should be taken with precaution since a higher load of operation (in order of 100’s of MPa to a few GPa) on the liquid lubricating film in the bearing results in a glassy state of the lubricant, where the lubricant does not have liquid-like properties [3234].

Contaminants and solid particles are part of the lubrication in case of presence of external particles, or solid particles eroded off the bearing surfaces [3543]. The effect of different particle types, sizes and concentration levels are studied by investigating current activity and number of breakdowns in bearing. The paper also aims to find differences in conduction properties of different particles, along with study of bearing resistance () during discharges. In a controlled laboratory environment, this study thus provides an analysis of breakdown of bearing voltage under current limiting conditions to avoid damages on bearing surfaces and to reuse test objects.

In field conditions, since an external HF source is driving the bearing currents, damages could occur on the bearing. Due to very small contact area, a breakdown will result in high current densities thus causing localized heating, melting damages and crater formation as well as re-hardening and brittling of surfaces. Discharge of energy stored in stray capacitances and the passage of current through the bearing can result in formation of micro-pits on the surfaces of the rolling elements and the raceways. The balls get a matte finish while the inner and the outer raceways develop an electrical fluting damage (or wash-boarding). It is evident from the morphology of the corroded surfaces that the micro-pits and corrugation pattern occur due to presence of an electrical stress during normal bearing operation as supported by [23, 24, 44, 45]. It is also reported that the time for the bearing to develop corrugation pattern prematurely, logarithmically follows the apparent current density of the electrical current [46]. Presence of particles result in scratches, indentations on bearing surfaces. The load of the operation could also result in embedding of foreign particles in the bearing raceways. Since ample investigations have already been done on this subject [23, 24, 44, 45]. Study related to the emergence of current initiated damage on surfaces of test bearings is thus not a scope of this publication.

In the industry, a bearing type is selected based on the operational conditions of the machine such as the operational speed and the radial and axial loading expected during operation. Nevertheless, the geometry of different types of bearings, i.e., point contact (e.g., ball bearing) or line contact (e.g., spherical bearing) will result in different contact and interacting profiles of the metallic surfaces. The breakdown of lubricant (bearing insulation) in the contact zone is thus influenced due to this geometric differences. Experimental investigations have shown that the breakdown field strength of bearing having line contact is found to be lower than that of point contact [47]. This is because for a same size of bearing, a bearing with line contact has more Hertzian contact area and thus higher chances of initiating a current path than a bearing with point contact.

1.3. Electrical Circuit Models of Bearing in Literature

The electrical circuit modelling found in literature is also based on similar line of thought. The focus was largely kept in modelling of the stray capacitances in the common mode equivalent circuit. In a simple version of the common-mode circuit model proposed by Busse et al. in [48], the bearing model forms a part of the common-mode equivalent circuit model along with the converter and the machine. The bearing model is represented by the capacitance , a nonlinear impedance and bearing resistance during the event of an electrical discharge (), shown in Figure 2. is shown to be variable since the bearing capacitance is a function of electrical properties of lubricant and the geometric separation between the tribological parts. The authors describe the non-linear device to represent the charging and discharging of the shaft, i.e., in other words, the occurrence of electrical breakdown events in the bearing. The authors propose that the metallic bearing elements such as raceways and rollers represent resistances which are having effective resistances , and respectively. Each roller is having a layer of lubricating film around itself, which is represented by , which forms near the inner and outer raceway respectively. This forms of an effective capacitance between each set of balls, which results in “” parallel capacitors. Furthermore, is added to the model to account for abnormal mechanical and electrical occurrences in the bearing. The nature of breakdown of the voltage across the bearing is termed a statistical and is dependent on the collapse of , which is to be determined through experiments. This breakdown of the bearing is hence said to be dependent on the position of the ball along with the condition of bearing surfaces and the lubricant’s electrical characteristics.

At higher speeds, the film is formed and the impedance of the bearing () is higher, reported to be in megaohm range. As the focus of majority of the studies has been kept on system level parameters and the emergence of different kinds of bearing currents, more emphasis can be given to elaborate the mechanisms with which the electrical breakdown events occur in the bearing. The motion of the bearing is complicated due to its dynamic nature and the variable nature of mechanical and electrical stresses and thus needs further elaboration. In the literature, the breakdown of bearing is also portrayed by a switch, but with arbitrarily chosen time of breakdown [7, 11]. The breakdown characteristics of lubricating film of bearing depend on many factors such as motion, magnitude of voltage across it, surface roughness of bearing, vibration levels, lubricant film properties, oil cleanliness among others.

To further the understanding of behavior of bearing during conducting state, rather recent experimental investigations [19] are reported on the nonsteady nature of electrical breakdown events of bearing under the influence of discharge bearing currents and HF voltage. The model proposed is on similar lines as the one proposed in this publication. The transition of the bearing from capacitive state (no breakdown) to ohmic state (breakdown) is dependent on the certain operating points such as speed and load, which the authors have termed as “Transition Activity, TRA”. In conclusion to their work, the general outcome was that the transition activity in bearing increases with an increase in temperature and the amplitude of the applied voltage. Bearing stays longer in resistive mode at lower speed, while it stays longer in capacitive mode at speed. Although, it is stated that the current conduction and breakdown mechanisms in rolling element bearings are only partially understood now.

2. Methods

This section details the description of the test objects, test bench, and the electrical circuit in which the bearing under test is connected. An overview of the analyses methods and the measurement are discussed in this section.

2.1. Test Objects and Test Setup

For the experiments, deep groove steel ball bearings of type SKF 608 with seven balls was used, shown in Figure 3. The outer diameter is 22 mm and the bore diameter is 8 mm. It is a miniature ball bearing and has high limiting speed of 48,000 revolutions per minute (rpm). The static load rating is 1.37 kN and the dynamic load rating is 3.45 kN. Cages made of Polyamide 6,6 separate the balls within the bearing. The test lubricant is composed of hydro-treated mineral type base oil blended with acrylic copolymer additives. The base oil viscosity is 100 mm2/s at 40°C and 11.4 mm2/s at 100°C [49]. The bearing is lubricated using an oil bath, with a level of 3 mm.

For the experiments, four test bearings were prepared after a running-in process of virgin bearings lubricated with particle-free oil sample for 4 hours, and a separate bearing was used for a given type of particle.

The lubricants used in experiments are shown below along with the particle type, concentration level and the size class of the particles. The highest particle concentration was chosen to be at 150 mg/L, since it is suggested to be the threshold of particle contamination by Elforsk in [35], a report on oil cleanliness in wind turbine gearboxes. Four different particles were used to prepare four versions of test lubricant, shown in Table 1. For Samples A1 and A2, five concentration levels ranging from 150 mg/L to 7.5 mg/L were prepared. Samples A3 and A4 were tested at a concentration level of 150 mg/L.

ATD comprises majorly of oxides of silicon (SiO2—68%) and aluminium (Al2O3—10%). Other smaller fractions include oxides of iron, sodium, calcium, and magnesium. Carbon black particles are taken from copy toner cartridge, and have a very small size (majority of the particles are smaller than 5 μm). Thus, there is a possibility that they cannot instantaneously bridge the gap at the inner and the outer raceways. Carbon black particles can hold electrical charge at the surface, and could thus coagulate on air bubbles in the lubricant. Aluminium and iron particles are chosen since they are electrically conducting in nature, thus they simulate electrically conducting properties of the bearing wear debris.

The bearing under test is mounted on a horizontal shaft together with a hybrid bearing, SKF hybrid bearing 608, with ceramic balls, shown in Figure 4. In this way, we have control over the current and discharge path through the bearing under test. The shaft is brought into rotation through a belt wheel and an insulating belt driven by a permanent magnet motor. A grounded U-girder, electrically insulated from the bearing housing, provides a solid foundation to the setup. Various levels of mechanical load can be applied by changing the position of the block. The axial load can be varied between 4 and 40 N [45]. The radial load is approximately 1 N on each bearing due to the weight of the shaft. The test bearing is axially loaded, which results in equal loading on all the balls in the bearing. The radial load slightly increases the load on the balls in the lower part of the bearing, due to weight of the shaft.

2.2. Cleaning Procedure

For the tests, the bearings were disassembled, and the surfaces were cleaned with isopropanol (99.9% pure), followed by use of sonication process of the parts of the bearing and the bearing housing unit for 5 minutes. The bearing was reassembled in a clean environment using rubber gloves to avoid the transfer of impurities from hands to the bearing surfaces. The assembled bearing and the housing were the dried using a heat gun at 50°C for 10 seconds to remove the residual isopropanol from the surfaces. After the cleaning procedure, the bearing housing and the bearing were remounted on the test rig, followed by lubrication with a given type of lubricant sample, shown in Table 1. The cleaning procedures were repeated in same manner before testing at a given concentration level. The sonication process helped in removal of small particles from the raceways and the housing that could not be wiped out with isopropanol.

2.3. Evaluation Methods

The bearing was operated at room temperature and in laboratory environment and was run for 5 minutes before any types of measurements were performed. The speed was set at 2000 rpm, corresponding to a speed factor of 30000 (given by product of rotational speed and bearing mean diameter of 15 mm for bearing type SKF 608), while the axial load is 4 N. Since the paper discusses the switching pattern analysis of the bearing during the conducting state, relevant evaluation methods are presented in this section.

The conducting state properties of a running bearing, i.e. characteristics of the switch and the bearing resistance , were evaluated by measuring the bearing voltage and the responding current through the bearing when a DC voltage was applied. In this study, the focus is on particle-initiated breakdowns, thus operating points were selected so that no breakdowns result due to asperity point contacts. A DC voltage of 5 V does not cause breakdown in the bearing, and are discussed in detail in reference measurements in results. As particle-initiated bridges are made between the inner and outer raceway of the bearing, the switch in the electrical circuit model closes and represents a making of a temporary conducting path for a flow of current.

The reason for using a DC voltage was to ensure that a bearing voltage was present always which enables the detection of a sudden bridging conductive path through the lubricant as a current. The test voltage, 5 V DC, was supplied from a stabilized DC power supply (CE-BIT LK 31) to the shaft by means of a slip ring contact though a current limiting resistance () to avoid possible current induced damages on the bearing surfaces, test circuit shown in Figure 4. The bearing voltage () is equal to . The current through bearing is measured as a voltage across a resistive shunt (); and is equal to . The resistors was chosen so that the current pulses recorded clearly can be distinguished from the noise level of 0.01 mA, hence a threshold of 0.1 mA was chosen to exclude effects from noise.

The insulation breakdown of the bearing was characterized with respect to different speeds and mechanical loads during operation. The bearing current activity due to particle-initiated breakdowns is quantified by the percentage time of conduction () during a measurement. is the fraction of time (in%) that the bearing is in conducting state can be calculated per Equation (1). The measurement window (tTotal) for each test is approximately 30 s, and “n” is the total number of breakdown events. The number of breakdowns per second are also shown for the measured point. The breakdowns are normalized per second to make comparisons between different tests.

The resistance is evaluated as the DC resistance of the bearing during conducting state from the ratio of bearing voltage and bearing current. The bearing voltage and the current through the bearing is recorded using a data acquisition card of type NI USB 6251. The data acquisition card offers a maximum aggregated sampling rate of 1 MS/s. Since we use two channels, the sampling rate will be 500 kS/s per channel. The bearing resistance is calculated during every breakdown event. Since the variation could be large, is presented in form of box plot to show the statistically significant values such as median, along with 75th percentile and 25th percentile of the data set which form the limits of the box.

2.4. Testing Procedure

The bearing was lubricated with a test oil sample and brought into rotation at the set operating parameter. During this start (Start 1), five measurements were conducted, where each measurement lasted for 30 s. The rotating bearing was stopped for a duration of 2 minutes to save the accumulated data. Same procedure was followed for the second (Start 2) and the third start sequences (Start 3). Hence, ten to fifteen measurements were done with every lubricant sample. This procedure was adopted to investigate the effect of start-stops on the insulation breakdown in bearing.

3. Results and Analyses

The results are broadly classified into two sections: conduction pattern analysis due to particle-initiated breakdowns and bearing resistance during the breakdowns.

3.1. Conduction Pattern Analysis
3.1.1. Reference Measurements

Before main tests, reference measurements with clean, particle-free fresh oil sample were conducted. For this, the bearing was disassembled, cleaned from the corrosion inhibitor grease, reassembled and lubricated with particle-free fresh oil sample. For all the tests in this section, the bearing was run at fixed operating point. The bearing was run at a speed of 2000 rpm, and an axial load of 4 N was applied, resulting in a total calculated lubricant film thickness of 1.37 μm, at 20°C. The film thickness between the inner and the balls is 0.58 μm, while between the outer ring and the ball is 0.75 μm.

For reference tests, no current activity was observed when 5 V DC is applied to it. Hence the reference level for all the experiments is at 0% , which refers to a bearing in fully insulating state. Thus, we can conclude that the bearing does not have asperity contact initiated breakdowns and voltage dependent breakdowns at these operating parameters. All breakdowns occurring will be only caused by particle-initiated three-body abrasion contacts, and the percentage time of conduction will be presented a function of particle concentration.

3.1.2. Conduction Pattern Analysis due to Particle-Initiated Breakdowns

The particle-initiated breakdowns in the bearing are characteristically different according to the type of particle used for contamination. The bearing voltage and the current activity during breakdown event is shown in Figure 5. A breakdown event are characterized by a sudden drop in bearing voltage and passage of current for the duration of the breakdown event. A breakdown event is relatively longer for Sample A1 compared to other samples. The bearing voltage and the bearing current activity also fluctuate less compared to other samples. Current activity in Sample A2 is relatively less compared to other samples. The break down events showing bearing voltage and current due to different particles is shown in Figure 5.

The results of the tests with Sample A1 are grouped in two separate charts, first chart with particle-concentration of 75 and 150 mg/L and second with particle concentrations 30, 15, and 7.5 mg/L and lower since the current activity varies by an order of magnitude. At a particle concentration of 150 mg/L, the number of breakdowns is in order of few 1000’s per second, as shown in Figure 6. In Start 1, the mean value of breakdowns is 4722 per second. For Start 2, number of breakdowns reduce to a mean value of 2426 per second. The reduction in number of breakdowns is a direct result of lesser number of particle bridges forming between the inner and the outer raceway of the bearing. This also results in reduction in from a mean value of 9.5% in Start 1 to a mean value of 4.4% in Start 2. At a lower particle concentration of 75 mg/L, the mean value is 2287 per second in Start 1 and 1415 per second in Start 2.

For particle concentration of 30 mg/L and lower, the number of breakdowns per second are in few 100’s per second accompanied with reduced , shown in Figure 7. The reduction in breakdowns and is due to removal of the particles from the load zone, and into the oil bath, and settling at the bottom of the sump due to gravitational force.

For tests with Sample A2, at a particle concentration of 150 mg/L, the breakdowns are significantly lower than Sample A1. The bearing has on an average of 16 breakdowns per second, corresponding to of 0.03%, (Figure 8). The number of breakdowns in Start 2 and Start 3 are higher compared to Start 1, and can be credited to the small size of the carbon black particles in conjunction with the ability to store charge on their surfaces, thus they could agglomerate on air bubbles. At 75 mg/L, the and breakdowns are reduced to half, and are shown in Figure 8. A particle concentration of 30 mg/L and lower results in less than 10 breakdowns per second, which corresponds to less than 0.01% . These results are not displayed due to space constraints.

For tests with Sample A3, the insulation breakdowns recorded ranges up to few 100’s per second, but the number reduces significantly in Start 1, (Figure 9). The breakdowns in the bearing are initially around 830 per second, but they reduce to less than 300 per second in the last three tests. Correspondingly, the is around 1.5% for the first two measurements in Start 1, but reduced to about 0.5% in the last three measurements. This indicates quick removal of large sized particles from the bearing during operation. After stopping and measuring for Start 2, the mean value of for five measurements is 0.1%, while it reduces to a mean value of 0.03% in Start 3. During Start 2 and Start 3, the breakdowns also reduced to less than 100 per second.

For tests with Sample A4, has breakdowns similar to Sample A1, but the decay in current activity is must faster. The is 8.24% at the first measurement in Test 1 resulting from 8258 breakdowns per second. The value subsequently drops to 2.8% (from 3278 breakdowns per second) in the fifth test of Start 1, indicating to a drop of number of iron particles in the loaded zone in Start 1. The trend continues in Start 2 and Start 3, and can be seen in Figure 10. During the tests, it is interesting to notice that systematically reduces with each measurement, along with the number of particle-initiated breakdowns per second. This indicates that these harder metallic particles undergo abrasion during operation and crumble in to smaller fragments due to fracture. It is seen from these measurements that the current activity is highest for Sample A1, followed by Sample A4, Sample A3 and Sample A2.

3.2. Evaluation of Equivalent Bearing Resistance () in Conducting State

A breakdown mechanism will result in a low resistance path, resulting in discharge of voltage and energy that are in parallel with the bearing, or when bearing is a part of a HF circulating current path. The low resistance path is offered by particles bridging the inner and outer raceway of the bearing. When the insulating properties of the bearing breaks down, there will be remaining resistance in path of the flow of current, which is a measure of . Depending on the type of particle, the mean value of during a single discharge event can vary significantly, shown in Figure 11. Analyses of RB for different particles at a fixed concentration level of 150 mg/L show that the median value ranges between 28 Ω and 63 Ω in case of Sample A1 and A2, while it is about 5–10 times higher for samples A3 and A4, Figure 11.

For Sample A1, the median value of remains at 28 Ω for all tests, while it relatively varies more for the other types of particles, as shown in Figure 12.

The measured data has the 75th and the 25th percentile values at 54 Ω and 20 Ω for Sample A1. The measured   remains rather constant, and does not change with the number of starts of the bearing, and the test sequence. For Sample A1, minimum value reached by is found to have a median value of 17 Ω in these tests, while the smallest value that could reach less than 1 Ω and could be a due to larger contact during breakdown event. Median values of are not affected by the concentration level of a type of particle, but rather by its size. The median values pulse duration stays approximately in the same order of magnitude for all different types of particles, but large spread is seen with Sample A3 that could be an effect of large sized particles.

Analyses of duration of discharges show that different particles appeared to cause the breakdown events for more or less for the same duration. This could be due to fix rotational speed of the bearing for different tests. The 75th percentile value of the measured pulse duration ranged up to 30 µs, while maximum values could reach up to 60 µs in case of aluminium powder. The aluminium powder particles were larger than all other particles tested, and hence stayed longer in the load zone until they fracture into smaller particles. The fine iron powder in Sample A4 are much smaller than aluminium powder and hence results in lower values of pulse duration during the breakdowns.

4. Conclusions

To establish a further understanding of electrical properties of a miniature bearing when exposed to a shaft voltage, an electric circuit model is proposed. The parameters associated with the two proposed electrical states are discussed and in this paper, the breakdown characteristics due to particles of different type, size, and concentrations is presented.

A breakdown of the bearing insulation requires the presence of an active mechanism that initiates the breakdown and a voltage source that drives the current through the bearing during the insulation breakdown.

It is concluded from these measurements that the current activity is highest for ATD, followed by iron powder, aluminium powder and carbon black particles. The current threshold limit of 150 mg/L for cleanliness levels in gear box oils in wind turbines is recommended to be lowered to 30 mg/L as the time of conduction is reduced by one order of magnitude.

Breakdowns initiated due to Arizona test dust reduce gradually during a given start, but the amount of particle bridges halve as the rotation of the bearing is stopped momentarily. The breakdowns also reduce to approximately to half in successive starts. On reduction of particle concentration level by 10 times, from 150 mg/L to 15 mg/L; the mean value of number of breakdowns reduce from 4722 per second to merely 203 per second in Start 1. During Start 2, the number of breakdown reduce to approximately half in both the cases.

Breakdowns initiated due to Carbon black particles are much shorter and much less compared to the Arizona test dust. This is credited to smaller size, possibly leading to their inability to form complete conducting bridges between the ball and the inner and outer raceways of the bearing. The discharges are 100 times lower than Arizona test dust particles, and the breakdowns are below 30 per second.

For Aluminum powder and fine iron powder, the number of breakdowns gradually reduces to a lower value as the tests are run. This indicates that these harder metallic particles undergo abrasion during operation and crumble in to smaller fragments due to fracture.

During a single particle-initiated breakdown event, the instantaneous value of RB varies significantly, and can vary up to several 100’s of ohms. This can be attributed to contact resistance offered by a multi-body contacts. The median value of RB ranges between 28 Ω and 63 Ω in case of Sample A1 and A2, while it is about 5–10 times higher for samples A3 and A4. For Sample A1, minimum value reached by is found to have a median value of 17 Ω in these tests, while the smallest value that could reach less than 1 Ω and could be a due to larger contact during breakdown event. The duration of discharge is approximately same for all the particles, and could be attributed to fixed speed during the experiments.

Data Availability

The breakdown data used to support the findings of this study are available from the corresponding author upon request.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

This publication is partially based on the doctoral thesis of Dr. Abhishek Joshi. This project is financed through the Swedish Wind Power Technology Centre (SWPTC). SWPTC is a research center for design of wind turbines. The purpose of the center is to support Swedish industry with knowledge of design techniques as well as maintenance in the field of wind power. The Centre is funded by the Swedish Energy Agency, Chalmers University of Technology as well as academic and industrial partners. The authors would like to thank Olle Bankeström of SKF Gothenburg for providing test samples, lab facilities, analyses and correspondence in the research project.