Research Article

Experimental Characterisation of Photovoltaic Modules with Cells Connected in Different Configurations to Address Nonuniform Illumination Effect

Table 3

Geometrical dimensions of the 2D CPC and V-trough collector.

ParameterCPC (before truncation)CPC (after truncation)V-trough

Acceptance half-angle (°)30.030.721.0
Trough angle (°)[-][-]10.0
Concentration ratio [-]2.01.961.96
Aperture width (mm)218.0213.64213.64
PV module width (mm)118.0118.0118.0
PV module length (mm)118.0118.0118.0
PV module active area (mm)109 × 109109 × 109109 × 109
Maximum height (mm)282.4212.07296.72
Collector maximum length (mm)500.0500.0500.0