Calculated parameters and data from simulations for Solarex MSX60.

ParametersMethod 1Method 2Ref. [25]Ref. [61]Ref. [70]Ref. [72]

Rs (Ω)0.1500.1500.2340.1690.21650.223427
Rsh (Ω)1148.498273.55349.29637.5274.937406.346152
A1.71.7371.271.4041.2771.387
Io (A)5.60956E − 67.46677E − 65.95E − 83.29E − 076.4500E − 82.97156E − 6
Iph (A)3.8000133.80013.83.8013.8133.872128
Io, equation (3) [55]5.60957E − 067.46678E − 065.95254E − 083.30851E − 076.56881E − 082.71080E − 07
Io, equation (3)5.58245E − 067.46177E − 062.39471E − 083.27969E − 076.43615E − 082.67376E − 07
Io, equation (13) [61]5.58319E − 067.46191E − 062.54464E − 083.28057E − 076.44132E − 082.67525E − 07
Io, equation (14)5.60956E − 067.46677E − 065.95254E − 083.30851E − 076.56881E − 082.71080E − 07
Io, equation (15)3.84169E − 065.09713E − 06−3.60728E − 073.28789E − 076.41383E − 082.26480E − 07
Io, equation (16)5.64471E − 067.11705E − 061.41800E − 075.69360E − 071.53585E − 074.84460E − 07
Io, equation (18)5.60657E − 067.49835E − 065.67053E − 083.19383E − 076.26165E − 082.61219E − 07