Research Article

A Fast and Accurate Analytical Method for Parameter Determination of a Photovoltaic System Based on Manufacturer’s Data

Table 2

Extracted parameters and data from simulations for BP3235T.

Rs (Ω)A<AoIo (A)Rsh (Ω)Iph (A)Voc (V)Voc (%)Pmpp (W)Pmpp (%)

Method 1
Rs10.0021.801956 (Ao)1.286446E − 52195.788.480037.194−0.016234.17−0.405
Rs20.24191.7921.194159E − 51146.068.481837.2010.003235.170.020
Rs30.2421.7921.194159E − 51066.378.481937.20235.12−0.001
Rs40.24211.7921.194159E − 5997.028.482137.199−0.003235.06−0.026
Rs40.24221.7921.194159E − 5936.108.482237.198−0.005235−0.052
Method 2
Rs10.08521.801956 (Ao)1.286446E − 56595.768.480137.20235.420.127
Rs20.24191.86261.989991E − 5992.728.482137.199−0.003232.96−0.920
Rs30.2421.86261.989991E − 51066.308.481937.199−0.003233.03−0.890
Rs40.24211.86261.989991E − 51151.688.481837.20233.09−0.864
Rs50.24221.86261.989991E − 51251.958.481737.2010.003233.14−0.843