Research Article

A Fast and Accurate Analytical Method for Parameter Determination of a Photovoltaic System Based on Manufacturer’s Data

Table 6

A summary of appropriate parameters for MSX60, BP-SX 150, KC200GT, and BP3235T.

MSX60BP-SX 150KC200GTBP3235T
Method 1Method 2Method 1Method 2Method 1Method 2Method 1Method 2

Rs (Ω)0.1500.1500.33010.33010.21880.21880.24200.2420
Rsh (Ω)1148.498273.55333866.6422158.121028.695679.351066.371066.30
A1.71.7371.962.0071.8091.8821.79201.8626
Io (A)5.6096E − 67.4668E − 062.9076E − 53.8513E − 51.6535E − 52.7501E − 51.1942E − 51.99E − 5
Iph (A)3.8000133.80014.75044.75018.21198.21278.4819388.4819