Table 8

Calculated parameters and data from simulations for KC200GT.

ParametersMethod 1Method 2Ref. [52]Ref. [55]Ref. [58]Ref. [61]Ref. [66]Ref. [59]

Rs (Ω)0.21880.21880.2170.2210.2310.2170.21080.21095
Rsh (Ω)953.941679.35951.927415.405594.851951.92145.083192.757
A1.8091.8821.341.31.31.3421.15781.1482
Io (A)1.6535E − 52.7501E − 51.7100E − 79.825E − 89.6990E − 81.71E − 71.01E − 88.6369E − 9
Iph (A)8.21198.21278.2128.2148.2138.2118.2268.218985
Io [55]1.6535E − 52.7501E − 51.6782E − 79.7328E − 89.7328E − 81.7230E − 71.0340E − 83.665E − 9
Io, equation (3)1.6466E − 52.7339E − 51.6711E − 79.6389E − 89.6672E − 81.7158E − 71.0054E − 83.568E − 9
Io, equation (13)1.6470E − 52.7348E − 51.6715E − 79.6440E − 89.6710E − 81.7162E − 71.0069E − 83.578E − 9
Io, equation (14)1.6535E − 52.7501E − 51.6782E − 79.7327E − 89.7327E − 81.7230E − 71.0340E − 83.665E − 9
Io, equation (15)8.2468E − 61.2462E − 51.6784E − 79.7440E − 89.6720E − 81.7164E − 71.1867E − 81.835E − 9
Io, equation (16)1.6783E − 52.5205E − 54.2778E − 72.7675E − 72.7675E − 74.3690E − 74.6099E − 82.012E − 8
Io, equation (18)1.6516E − 52.7700E − 51.6014E − 79.2594E − 89.2594E − 81.6445E − 79.7438E − 93.443E − 9