Research Article

Technical Evaluation of Photovoltaic Systems in the Bamenda Municipality of the North West Region of Cameroon

Table 1

System capacity in a selected household.

S/NComponentQuantityUnit capacityTotal capacityRemarks

1PV generator4160 Wp640 Wp = 7.96 A
 = 20.2 A
 = 9.33 A,  = 21.84 V
The panels were monocrystalline connected in series

2Battery3150 Ah450 AhEach battery was rated 12 V, sealed gel lead acid battery

3Charge controller140 A 12 V/24 V40 A 12 V/24 V

4Inverter12000 W2000 WPure sine wave

5Surge protective device (SPD)12.2 kV2.2 kVProtect the charge controller from surge voltage in case of a lightning storm