Research Article

Technical Evaluation of Photovoltaic Systems in the Bamenda Municipality of the North West Region of Cameroon

Table 4

Comparison of an installed SPVS and a redesign system.

Component of the SPVSInstalled capacityRedesigned capacityRemarks

PV array640 Wp980 WpUndersized
Battery bank450 Ah525 AhUndersized
Charge controller40 A, 12 V/24 V80 A, 12 V/24 VUndersized
Inverter2000 W2236 WUndersized