Microwave-Assisted Extraction Studies of Target Analyte Artemisinin from Dried Leaves of Artemisia annua L.
Table 2
Influence of mesh, solvent volume, time, and power of microwave irradiation on recovery of artemisinin.
Solvent
Material to solvent ratio
Particle size (Mesh)
Irradiation time/cycle (Second)
Irradiation power (Watt)
% Mean artemisinin recovered (±SD) (% dry weight)bn = 3
% RSD
Acetonea
100 mg : 5 mL
14
60
160
0.63 (±0.01)
1.59
Acetone
100 mg : 5 mL
60
160
0.64 (±0.02)
2.40
25
60
320
0.64 (±0.02)
3.13
120
160
0.69 (±0.01)
0.84
Acetone
100 mg : 10 mL
60
160
0.71 (±0.01)
1.63
25
60
320
0.69 (±0.02)
2.90
120
160
0.73 (±0.01)
1.37