Research Article

Cost-Saving Early Diagnosis of Functional Pain in Nonmalignant Pain: A Noninferiority Study of Diagnostic Accuracy

Table 2

Noninferiority comparison of peg and electronic algometry in discerning functional from nociceptive pain: areas under the receiver operating characteristic curves (AUC).

AUC in % of a perfectly discerning test (95% CI)Difference (95% CI) value
Peg algometryElectronic algometryCrudeAUC of peg minus 95% of the AUC of electronic algometry

Finger measures79 (71 to 86)72 (64 to 80)7 (−3 to 16) 0.1811 (1 to 20) 0.04
Ear measures81 (74 to 88)66 (57 to 75)15 (5 to 24) 0.00318 (8 to 27) < 0.001

No missing data.