Research Article

Ovary-Sparing Radiation Planning Techniques Can Achieve Ovarian Dose Reduction for Soft Tissue Sarcoma of the Buttock and Thigh

Table 3

Dosimetric comparison of mean bilateral ovary dose (MBOD) and mean contralateral ovary dose (MCOD) for standard plans and ovary-sparing plans by anatomic location ().

Tumor distance from pubic symphysisStandard planOvary-sparing plan value

Tumor < 8 cm from pubic symphysis, MBOD (cGy) (SD)10619
(765)
376
(540)
0.018
Tumor 8 cm from pubic symphysis, MBOD (cGy) (SD)13678
(1184)
566
(1022)
0.17
Tumor < 8 cm from pubic symphysis, MCOD (cGy) (SD)10249
(575)
72
(109)
0.128
Tumor 8 cm from pubic symphysis, MCOD (cGy) (SD)13211
(277)
86
(442)
0.222
Tumor subsite, MBOD (cGy)
 Proximal medial thigh (SD)13445
(721)
293
(494)
0.008
 Other thigh, MBOD (SD)695
(217)
19
(309)
0.33
 Buttock, MBOD (SD)42161
(1170)
1800
(1116)
0.20
Tumor subsite, MCOD (cGy)
 Proximal medial thigh (SD)13167
(255)
70
(50)
0.12
 Other thigh, MBOD (SD)68.8
(15.6)
7.2
(11.6)
0.36
 Buttock, MBOD (SD)4781
(881)
210
(104)
0.26

MBOD: mean bilateral ovary dose; SD: standard deviation; cGy: centigray.