Research Article

Ovary-Sparing Radiation Planning Techniques Can Achieve Ovarian Dose Reduction for Soft Tissue Sarcoma of the Buttock and Thigh

Table 4

Univariate and multivariate analysis of likelihood of reduction in mean bilateral ovary dose (MBOD) with an ovary-sparing plan.

Reduction in
MBOD
No reduction
in MBOD
UVA
value
MVA
value

Mean distance to pubic symphysis (cm) (95% CI)6.3
(4.5, 8.1)
14.1
(8.2, 19.9)
0.0038
Site, number (%)
 Proximal medial thigh10 (77%)3 (23%)
 Buttock3 (75%)1 (25%)
 Other thigh1 (17%)5 (83%)0.048
Largest GTV dimension (cc) (95% CI)8.7
(5.6, 11.8)
9.5
(6.0, 13.0)
0.054

MBOD: mean bilateral ovary dose; SD: standard deviation; UVA: univariate analysis; MVA: multivariate analysis; cm: centimeter; cc: cubic centimeter. -test value. Fisher’s exact value. Logistic regression chi-square value.