Table of Contents
Smart Materials Research
Volume 2013, Article ID 498019, 16 pages
http://dx.doi.org/10.1155/2013/498019
Research Article

Development and Application of One-Sided Piezoelectric Actuating Micropump

Department of Mechanical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan

Received 8 March 2013; Accepted 4 September 2013

Academic Editor: Osama J. Aldraihem

Copyright © 2013 H. K. Ma et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. S. Böhm, W. Olthuis, and P. Bergveld, “A plastic micropump constructed with conventional techniques and materials,” Sensors and Actuators A, vol. 77, no. 3, pp. 223–228, 1999. View at Publisher · View at Google Scholar · View at Scopus
  2. C. Yamahata, F. Lacharme, Y. Burri, and M. A. M. Gijs, “A ball valve micropump in glass fabricated by powder blasting,” Sensors and Actuators B, vol. 110, no. 1, pp. 1–7, 2005. View at Publisher · View at Google Scholar · View at Scopus
  3. E. Stemme and G. Stemme, “A valveless diffuser/nozzle-based fluid pump,” Sensors and Actuators A, vol. 39, no. 2, pp. 159–167, 1993. View at Google Scholar · View at Scopus
  4. A. Olsson, G. Stemme, and E. Stemme, “Diffuser-element design investigation for valve-less pumps,” Sensors and Actuators A, vol. 57, no. 2, pp. 137–143, 1996. View at Publisher · View at Google Scholar · View at Scopus
  5. W. L. Benard, H. Kahn, A. H. Heuer, and M. A. Huff, “Thin-film shape-memory alloy actuated micropumps,” Journal of Microelectromechanical Systems, vol. 7, no. 2, pp. 245–251, 1998. View at Publisher · View at Google Scholar · View at Scopus
  6. O. Francais, I. Dufour, and E. Sarraute, “Analytical static modelling and optimization of electrostatic micropumps,” Journal of Micromechanics and Microengineering, vol. 7, no. 3, pp. 183–185, 1997. View at Publisher · View at Google Scholar · View at Scopus
  7. A. Wego, H.-W. Glock, L. Pagel, and S. Richter, “Investigations on thermo-pneumatic volume actuators based on PCB technology,” Sensors and Actuators A, vol. 93, no. 2, pp. 95–102, 2001. View at Publisher · View at Google Scholar · View at Scopus
  8. C. R. de Lima, S. L. Vatanabe, A. Choi, P. H. Nakasone, R. F. Pires, and E. C. Nelli Silva, “A biomimetic piezoelectric pump: computational and experimental characterization,” Sensors and Actuators A, vol. 152, no. 1, pp. 110–118, 2009. View at Publisher · View at Google Scholar · View at Scopus
  9. J. Kan, K. Tang, G. Liu, G. Zhu, and C. Shao, “Development of serial-connection piezoelectric pumps,” Sensors and Actuators A, vol. 144, no. 2, pp. 321–327, 2008. View at Publisher · View at Google Scholar · View at Scopus
  10. P. Skafte-Pedersen, D. Sabourin, M. Dufva, and D. Snakenborg, “Multi-channel peristaltic pump for microfluidic applications featuring monolithic PDMS inlay,” Lab on a Chip, vol. 9, no. 20, pp. 3003–3006, 2009. View at Publisher · View at Google Scholar · View at Scopus
  11. M. Holtappels, M. Stubbe, and J. Gimsa, “Ac-field-induced fluid pumping in microsystems with asymmetric temperature gradients,” Physical Review E, vol. 79, no. 2, Article ID 026309, 10 pages, 2009. View at Publisher · View at Google Scholar · View at Scopus
  12. E.-G. Kim, J.-G. Oh, and B. Choi, “A study on the development of a continuous peristaltic micropump using magnetic fluids,” Sensors and Actuators A, vol. 128, no. 1, pp. 43–51, 2006. View at Publisher · View at Google Scholar · View at Scopus
  13. H. K. Ma, B. R. Hou, H. Y. Wu, C. Y. Lin, J. J. Gao, and M. C. Kou, “Development and application of a diaphragm micro-pump with piezoelectric device,” Microsystem Technologies, vol. 14, no. 7, pp. 1001–1007, 2008. View at Publisher · View at Google Scholar · View at Scopus
  14. H.-K. Ma, B.-R. Hou, C.-Y. Lin, and J.-J. Gao, “The improved performance of one-side actuating diaphragm micropump for a liquid cooling system,” International Communications in Heat and Mass Transfer, vol. 35, no. 8, pp. 957–966, 2008. View at Publisher · View at Google Scholar · View at Scopus
  15. H.-K. Ma, B.-R. Chen, J.-J. Gao, and C.-Y. Lin, “Development of an OAPCP-micropump liquid cooling system in a laptop,” International Communications in Heat and Mass Transfer, vol. 36, no. 3, pp. 225–232, 2009. View at Publisher · View at Google Scholar · View at Scopus
  16. H. K. Ma, H. C. Su, and J. Y. Wu, “Study of an innovative one-sided actuating piezoelectric valveless micropump with a secondary chamber,” Sensors and Actuators A, vol. 171, no. 2, pp. 297–305, 2011. View at Publisher · View at Google Scholar · View at Scopus
  17. J. Kan, Z. Yang, T. Peng, G. Cheng, and B. Wu, “Design and test of a high-performance piezoelectric micropump for drug delivery,” Sensors and Actuators A, vol. 121, no. 1, pp. 156–161, 2005. View at Publisher · View at Google Scholar · View at Scopus
  18. J. M. Gere, Mechanics of Materials, Brooks Cole, Pacific Grove, Calif, USA, 5th edition, 2001.
  19. L. D. Landau and E. M. Lifshitz, Theory of Elasticity, Pergamon, Oxford, UK, 1986.
  20. W.-J. Sheu, R.-T. Huang, and C.-C. Wang, “Influence of bonding glues on the vibration of piezoelectric fans,” Sensors and Actuators A, vol. 148, no. 1, pp. 115–121, 2008. View at Publisher · View at Google Scholar · View at Scopus
  21. L. S. Pan, T. Y. Ng, X. H. Wu, and H. P. Lee, “Analysis of valveless micropumps with inertial effects,” Journal of Micromechanics and Microengineering, vol. 13, no. 3, pp. 390–399, 2003. View at Publisher · View at Google Scholar · View at Scopus
  22. L. S. Pan, T. Y. Ng, G. R. Liu, K. Y. Lam, and T. Y. Jiang, “Analytical solutions for the dynamic analysis of a valveless micropump—a fluid-membrane coupling study,” Sensors and Actuators A, vol. 93, no. 2, pp. 173–181, 2001. View at Publisher · View at Google Scholar · View at Scopus
  23. V. Ziebart, O. Paul, U. Münch, J. Schwizer, and H. Baltes, “Mechanical properties of thin films from the load deflection of long clamped plates,” Journal of Microelectromechanical Systems, vol. 7, no. 3, pp. 320–328, 1998. View at Publisher · View at Google Scholar · View at Scopus
  24. A. Ullmann, “The piezoelectric valve-less pump—performance enhancement analysis,” Sensors and Actuators A, vol. 69, no. 1, pp. 97–105, 1998. View at Google Scholar · View at Scopus
  25. S. S. Rao, Mechanical Vibrations, Pearson Prentice Hall, New Jersey, NJ, USA, 4th edition, 2004.
  26. Y. C. Hsiao, Numerical analysis of a valveless One-side actuating piezoelectric micopup [M.S. thesis], National Taiwan University, Taipei, Taiwan, 2009.
  27. H.-K. Ma, S.-H. Huang, J.-S. Wang, C.-G. Hou, C.-C. Yu, and B.-R. Chen, “Experimental study of a novel piezoelectric proton exchange membrane fuel cell with nozzle and diffuser,” Journal of Power Sources, vol. 195, no. 5, pp. 1393–1400, 2010. View at Publisher · View at Google Scholar · View at Scopus
  28. H.-K. Ma, J.-S. Wang, and Y.-T. Chang, “Development of a novel pseudo bipolar piezoelectric proton exchange membrane fuel cell with nozzle and diffuser,” Journal of Power Sources, vol. 196, no. 8, pp. 3766–3772, 2011. View at Publisher · View at Google Scholar · View at Scopus
  29. H.-K. Ma, J.-S. Wang, W.-H. Su, and W.-Y. Cheng, “The performance of a novel pseudo-bipolar bi-cell piezoelectric proton exchange membrane fuel cell with a smaller nozzle and diffuser,” Journal of Power Sources, vol. 196, no. 18, pp. 7564–7571, 2011. View at Publisher · View at Google Scholar · View at Scopus