Research Article
Floorplan-Driven Multivoltage High-Level Synthesis
Table 7
Experimental results on total energy consumption (pJ).
| Benchmark | Separate Flow | Integrated Flow | Improvement (%) | Wire | Datapath | Total | Time (s) | Wire | Datapath | Total | Time (s) | Wire | Datapath | Total |
| EWF | 7286 | 13634 | 20920 | 5.34 | 4138 | 14547 | 18685 | 16.22 | 43.2 | | 10.7 | IIR | 6892 | 13285 | 20177 | 1.69 | 4287 | 13843 | 18130 | 4.77 | 37.8 | | 10.1 | DCT | 10275 | 23663 | 33938 | 9.01 | 5620 | 25509 | 31129 | 62.04 | 45.3 | | 8.3 | DiffEq | 4100 | 7852 | 11952 | 0.21 | 2476 | 8152 | 10628 | 1.05 | 39.6 | | 11.1 | FDCT | 11236 | 21773 | 33009 | 9.30 | 5315 | 23754 | 29069 | 55.64 | 52.7 | | 12.0 | FIR | 7967 | 9191 | 17158 | 4.69 | 5035 | 9384 | 14419 | 30.21 | 36.8 | | 16.0 | TFIR | 8360 | 16442 | 24802 | 1.84 | 5743 | 16985 | 22728 | 12.37 | 31.3 | | 8.4 | Lattice | 8261 | 20637 | 28898 | 1.98 | 4337 | 23567 | 27904 | 13.08 | 47.5 | | 3.4 | Average | — | — | — | — | — | — | — | — | 42.6 | | 9.5 |
|
|