Research Article

A Discrete Event System Approach to Online Testing of Speed Independent Circuits

Table 1

A partial list of faults and their effects on STG.

Fault type Effect of fault on the transitions

Transistor stuck-on fault for C1 + can only be fired after +, −, and − (the same as normal condition)

Transistor stuck-on fault for C1 + can be fired after either − or

Transistor stuck-on fault for C1 − can be fired after either + or +

Transistor stuck-on fault for C1 − can only be fired after + and +

Transistor stuck-on fault for C2 + can be fired after +

Transistor stuck-on fault for C2 + can be fired after +

Transistor stuck-on fault for C2 − can be fired after

Transistor stuck-on fault for C2 − can be fired after

Transistor stuck-off fault for C1 All arcs from + are always 0

Transistor stuck-off fault for C1 All arcs from + are always 0

Transistor stuck-off fault for C1 All arcs from − are always 0

Transistor stuck-off fault for C1 All arcs from − are always 0

Transistor stuck-off fault for C2 All arcs from + are always 0

Transistor stuck-off fault for C2 All arcs from + are always 0

Transistor stuck-off fault for C2 All arcs from − are always 0

Transistor stuck-off fault for C2 All arcs from − are always 0

Transistor stuck-on fault for C1
Transistor stuck-off fault for C1
All arcs from + are always 0

Transistor stuck-on fault for C1
Transistor stuck-off fault for C1
All arcs from − are always 0

Transistor stuck-on fault for C2
Transistor stuck-off fault for C2
All arcs from − are always 0

Transistor stuck-on fault for C2
Transistor stuck-off fault for C2
All arcs from + are always 0

Stuck-at-0 fault at Line 1 or Line 2 or Line 3
Stuck-at-0 fault at Line 6 or Line 7
Stuck-at-1 fault at Line 9 or Line 10
All arcs from + are always 0

Stuck-at-0 fault at Line 4 and Line 5 All arcs from + are always 0

Stuck-at-1 fault at Line 4 or Line 5
Stuck-at-1 fault at Line 6 or Line 7
Stuck-at-0 fault at Line 9 or Line 10
All arcs from − are always 0

Stuck-at-0 fault at Line 8 All arcs from + are always 0 and all arcs from + are always 0

Stuck-at-1 fault at Line 8 All arcs from − are always 0 and all arcs from − are always 0

Stuck-at-0 at Line 11 All arcs from − are always 0 and all arcs from + are always 0

Stuck-at-1 fault at Line 11 All arcs from + are always 0 and all arcs from − are always 0

Stuck-at-0 fault at Line 12 or Line 13 All arcs from + are always 0

Stuck-at-1 fault at Line 12 or Line 13 All arcs from − are always 0