Research Article
New Pulse Width Modulation Technique to Reduce Losses for Three-Phase Photovoltaic Inverters
Table 5
Calculation results of the switching losses when different modulation techniques are used.
| Modulation type | Central PWM | 60° PWM | 120BCM |
| RG4PH40UDPbF-IGBT |
| Turn-on losses [W] | 25.83 | 12.96 | 2.88 | Turn-off losses [W] | 33.01 | 17.05 | 3.96 | Total losses [W] | 58.84 | 30.01 | 6.84 | Total inverter losses [W] | 353.07 | 180.06 | 41.04 |
| C3M0065090D-SiC |
| Turn-on losses [W] | 3.59 | 1.80 | 0.40 | Turn-off losses [W] | 1.73 | 0.89 | 0.21 | Total losses [W] | 5.32 | 2.69 | 0.61 | Total inverter losses [W] | 31.92 | 16.14 | 3.66 |
|
|
Sum of all switching losses by all six switches. |