Research Article

Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method

Table 2

System suitability parameters for the determination of the atenolol and trimetazidine in pure form/human urine.

ParametersAtenololTrimetazidine Reference value [39, 40]

Retention time ()3.72/4.324.31/5.79-----
Number of theoretical plates (N)13211/289613935/13668>2000
increase with efficiency of separation
Tailing factor (T)0.97/1.850.71/1.11≤2
Capacity factor “Mass distribution ratio” (K′)2.44/2.322.98/3.461-10 acceptable
Height equivalent to one theoretical plate (HETP)0.01/0.040.01/0.01The smaller the value, the higher the column efficacy
Resolution 1.62/4.89>1.5
Good separation between peaks of interest.
Selectivity factor (α)1.11/1.49> 1