Research Article
Planning of Hybrid Micro-Hydro and Solar Photovoltaic Systems for Rural Areas of Central Java, Indonesia
Table 6
NPC for various configurations of the hybrid power plant systems.
| Number | Configuration of hybrid power plant | Net present cost (US $) |
| 1 | Grid + micro-hydro | −1,732,441 | 2 | Grid + micro-hydro + PV 10 kW | −1,546,092 | 3 | Grid + micro-hydro + PV 20 kW | −1,521,004 | 4 | Grid + micro-hydro + PV 30 kW | −1,518,933 | 5 | Grid + micro-hydro + PV 40 kW | −1,515,277 |
|
|