PatientSexAgeOperative procedureComplicationsTimeEBLLOSDispoIliac screwsCT confirmation of iliac screw placement

JBM68L1-iliac MIS instrumented fusion with L2-S1 MIS TLIFNone3608004Home65 mm × 8 mmYes, correct position
DKF75T10-iliac MIS instrumented fusion with L2-S1 MIS TLIFNone3205005Home80 mm × 8 mmYes, correct position
HSF78T9-iliac MIS instrumented fusion with L1-S1 MIS TLIFNone3405507Home65 mm × 8 mmYes, correct position
JLF72T9-iliac MIS instrumented fusion with L1–5 MIS TLIFNone3004506Home80 mm × 8 mmYes, correct position
KFF62T11-iliac MIS instrumented fusion with L5-S1 MIS TLIFNone2652505Home65 mm × 8 mmYes, correct position
ESF76T10-iliac MIS instrumented fusion with L2-S1 MSI TLIFT10 and L5 screw breaches3105008Rehab80 mm × 8 mmYes, correct position
RSF75T12-iliac MIS instrumented fusion with L2-S1 MSI TLIFNone3104004Rehab65 mm × 8 mmYes, correct position
BPM80L2-iliac MIS instrumented fusion with L2-S1 MIS TLIFNone2804505Home80 mm × 8 mmYes, correct position
SRF66T9-iliac MIS instrumented fusion with L1–5 MIS TLIFEpidural hematoma requiring laminectomy for evacuation3005007Rehab65 mm × 8 mmYes, correct position
RLM78L2-iliac MIS instrumented fusion with L2-S1 MIS TLIFNone2403955Home80 mm × 8 mmYes, correct position