Research Article
Resolution-Free Accurate DNA Contour Length Estimation from Atomic Force Microscopy Images
Table 6
Error analysis of
, , and
, .
| | Error | Estimator | | Relative (%) | Absolute (nm) | std (nm) |
| | 340 | 0.05 | 0.19 | 3.6 | 680 | 0.00001 | 0.00009 | 4.51 | 1020 | 0.02 | 0.20 | 5.23 |
| | 340 | 0.26 | 0.99 | 4.71 | 680 | 0.24 | 1.67 | 6.18 | 1020 | 0.24 | 2.45 | 7.36 |
| | 340 | 3.42 | 11.63 | 4.86 | 680 | 3.40 | 23.12 | 6.38 | 1020 | 3.39 | 34.63 | 7.60 |
|
|