Research Article

Application of ASTEC, MELCOR, and MAAP Computer Codes for Thermal Hydraulic Analysis of a PWR Containment Equipped with the PCFV and PAR Systems

Table 2

Main results of the in-vessel severe accident analysis important for the latter containment behaviour.

ParameterASTECMELCORMAAP

Mass of water released from the RCS before the RPV failure128000 kg105000 kg130000 kg
Mean mass flow rate at the break11 kg/s9 kg/s11 kg/s
Temperature of released water/steam600–1100 K600–1100 K600–1000 K
Mass of hydrogen produced in the RPV268 kg211 kg265 kg
RCS pressure at the time of the RPV failure5.6 MPa7.8 MPa6.9 MPa
Mass of material released from the RPV85700 kg87500 kg88000 kg
Temperature of released material2400 K2120 K2330 K
Long term decay heat level in the material accumulated in the cavity4–14 MW