Research Article

Analysis and Research on the Centimeter Band Receiver Amplitude Calibration Method

Table 2

Test data and comparison results for the cold and ambient load method.

T amb (K)V amb (uW)T cold (K)V cold (uW)T rec (K)E (%)

295.766.7777.946.35416.32.4
295.666.767846.39417.42.7
295.666.7878.246.48419.43.2
295.966.9677.946.54418.83.0
295.266.987846.72422.74.0