Research Article

Center Impedance Method for Damping Measurement

Table 2

Specifications of thin bars used for Oberst and Center Impedance.

BATCH R 690-64 R 690-64

Beam typeOberstCenter impedance
Boundary conditionCantileveredFree-Free
Material density1057 (kg/m3)1057 (kg/m3)
Material thickness0.00318 m0.0030 m to 0.004 m
Beam length0.2 m0.305 m
Beam width0.0127 m0.0305 m