Research Article

Whole-Body Vibration Sensor Calibration Using a Six-Degree of Freedom Robot

Table 3

The peak-to-peak displacements and frequency settings used for the high g calibration verification and resulting ± approximate peak acceleration amplitude values.

Peak-to-peak displacement (mm)Frequency (Hz)Approximate acceleration (g)

5.08101.02
1.27201.01
3.81151.72
2.54202.03
3.81203.04
2.54253.17
1.27353.08
5.08204.06