The severity of unbalance.

Exact valueIdentified valueError

Case  1unbalance [g mm]12.012.90.9
angle [deg.]0−9.9−9.9

Case  2unbalance [g mm]12.013.21.2
angle [deg.]4545.40.4

Case  3unbalance [g mm]12.013.21.2
angle [deg.]9088.9−1.1

Case  4unbalance [g mm]12.013.21.2
angle [deg.]135136.41.4

Case  5unbalance [g mm]12.013.21.2
angle [deg.]180179.9−0.1

Case  6unbalance [g mm]12.012.90.9
angle [deg.]225227.42.4

Case  7unbalance [g mm]12.012.60.6
angle [deg.]270270.90.9

Case  8unbalance [g mm]12.012.60.6
angle [deg.]315310.4−4.6