Research Article
Stepwise Diagnosis for Rotating Machinery Using Force Identification Approach
Table 2
The severity of unbalance (Disk 1).
| | | Exact value | Identified value | Error |
| Case 1 | unbalance [g·mm] | 12.0 | 13.7 | 1.7 | angle [deg.] | 0 | −15.9 | −15.9 |
| Case 2 | unbalance [g·mm] | 12.0 | 14.1 | 2.1 | angle [deg.] | 45 | 33.1 | −12.0 |
| Case 3 | unbalance [g·mm] | 12.0 | 14.0 | 2.0 | angle [deg.] | 90 | 77.0 | −13.0 |
| Case 4 | unbalance [g·mm] | 12.0 | 12.9 | 0.9 | angle [deg.] | 135 | 120.9 | −14.1 |
| Case 5 | unbalance [g·mm] | 12.0 | 11.5 | −0.5 | angle [deg.] | 180 | 164.9 | −15.1 |
| Case 6 | unbalance [g·mm] | 12.0 | 11.7 | −0.3 | angle [deg.] | 225 | 204.4 | −20.6 |
| Case 7 | unbalance [g·mm] | 12.0 | 12.5 | 0.5 | angle [deg.] | 270 | 244.0 | −26.0 |
| Case 8 | unbalance [g·mm] | 12.0 | 12.5 | 0.5 | angle [deg.] | 315 | 300.8 | −14.2 |
|
|