Research Article

Fault Diagnosis of Beam-Like Structure Using Modified Fuzzy Technique

Table 4

Computed nondimensional natural frequencies and mode shape differences of fixed-fixed beam.

Sl. numberTest pointsNondimensional natural frequencyNondimensional mode shape differences

1Uncrack0.0001.0001.0001.0000.0000.0000.000
20.1250.2000.9390.9540.9410.2650.2390.302
30.1250.3000.9250.9510.9390.3730.3050.373
40.1250.4000.9120.9430.9490.1620.0250.081
50.2500.2000.9330.9560.9420.127āˆ’0.0850.174
60.2500.3000.9260.9490.9410.0170.8110.234
70.2500.4000.9190.9490.9270.1820.0570.404
80.3750.2000.9260.9410.9450.0750.2240.372
90.3750.3000.9210.9410.9390.0770.3090.379
100.3750.4000.9290.9380.939āˆ’0.0420.3110.381